Approach 2* According to EN 1997-1

RF‑/FOUNDATION Pro introduced the geotechnical design of single foundations according to EN 1997‑1 in RFEM 5 and RSTAB 8. Depending on the National Annex preset in the add‑on module, you can determine the bearing resistance using Approach 2 or 3 in compliance with EN 1997‑1 up to Version x.04.0108.

Starting with program version x.05.0018, there is an additional Approach 2* for the determination of bearing resistance.

The essential difference between Approach 2 and Approach 2* is that the determination of bearing resistance according to Approach 2* applies characteristic values of loading. This has a favorable influence on the eccentricity and load inclination used in the bearing resistance equation.

You can select the approach for the bearing resistance determination under Parameters of the National Annex (see the image). The availability of the individual approaches depends on the National Annex selected in Window 1.1.

The program automatically determines the characteristic loads as initial values for each load combination entered in Window 1.4 under Structural (STR) and Geotechnical (GEO) to determine the bearing resistance using Approach 2*.

In summary, you can use Approach 2* especially for significantly eccentric loading situations to achieve efficient foundation dimensions if the ground failure design is relevant for the foundation dimensions.


Author

Mr. Kieloch provides technical support to our customers and is responsible for development in the area of reinforced concrete structures.